中文 / ENGLISH
申贝 感光 材料
Contact Us | Reture Home | For Collection  
 
Home News Honor Recruitment Contact Us  
X-ray film for medical us
Industrial X-ray film
Color Inkjet Paper
Black and white film, fil
Black and white photograp
the paper testing the sul
He-Ne laser illumination
UV oscillographic recordi
Technical Support
 
 

Product features

 

big axial sub-dividing medical film is imported from Germany
1 ShangHai medical X-ray film(GK - III)
Features: It be used imported film from Germany.It is big axial sub-dividing filmed processing tolerance。The film is medium high speed, low fog ,rich gradation ,good sharpness and low X-ray exposure to human body. The film is suitable for general X-ray photography. The film can be used with blue-emitted intensifying screen.
                                 
2 ShangHai medical X-ray film(NK - 1)
Features: It be used imported film from Germany.It is big axial sub-dividing filmed processing tolerance. The film is used for processing in an automatic processing machine at high temperature. It is high speed ,medium contrast ,low fog and fine grains.It can not only reduce the X-ray exposure dose used by patient ,but also improve the sharpness of the image.The film is suitable for general X-ray photograghy. The film can be used with blue-emitted intensifying screen.
 
3 ShangHai medical X-ray film (NKG – 3)
Features: It be used imported film from Germany.It is big axial sub-dividing filmed processing tolerance.It can obtain higher photographic. It is medium speed and the medium contrast,low fog and fine grais at room temperature. The film is suitable for general X-ray photograghy. The film can be used with green-emitted intensifying screen.
 
 
large axle sub-dividing medical film is imported from Japan
1 ShangHai  medical X-ray (GK–V)
Features: It is used imported film from Japan.It is big axial sub-dividing filmed processing tolerance.It can obtain higher photographic at room temperature It is medium speed and contrast,low fog and fine grains.The film is suitable for general X-ray photograghy. The film can be used with blue-emitted intensifying screen.
 
2 ShangHai medical X-ray (NK–3)
Features: It is used imported film from Japan.It is big axial sub-dividing filmed processing tolerance. The film is used for processing in an automatic processing machine at high temperature. It is medium speed ,medium contrast ,low fog and fine grains. The film is suitable for general x ray photograghy. The film can be used with blue-emitted intensifying screen.
 
3 ShangHai medical X-ray (NKG-3)
Features: It is used imported film from Japan.It is big axial sub-dividing filmed processing tolerance. The film is used for processing in an automatic processing machine at higher temperature. It is medium speed ,medium contrast,low fog and fine grains.The film can be used with blue-emitted intensifying screen.
     
 

 

 Specification and Package
 
SPECIFICATION
PACKAGE OF NK SERIES
PACKAGE OF GK SERIES
BRITISH
BRITISH
(inch)
METRIC SYSTENM(mm)
CASE
CONT
PAPER
BOX
CONT
(CASE)
WEIGHT(kg)
MEAS
(mm)
CASE
CONT
PAPER
BOX
CONT
(CASE)
WEIGHT
(kg)
 MEAS
(mm)
5×7×100s
127×178×100s
100
5
4
218×200×174
50
20
15
400×340×240
8×10×100s
203×254×100s
100
5
8.5
304×200×249
50
10
14
400×315×250
10×12×100s
254×305×100s
100
5
12.5
378×200×249
50
10
22
400×360×300
11×14×100s
279×356×100s
100
5
15.5
430×200×325
50
5
13
410×210×330
12×15×100s
305×381×100s
100
5
17.5
445×200×352
50
5
15
435×210×350
14×14×100s
356×356×100s
100
5
19.5
430×200×403
50
5
18
400×210×420
14×17×100s
356×432×100s
100
5
23
510×205×410
50
5
20
480×210×420
 
  Processing Conditions
 

Automatic developing:
Suitable for various types of the washing machine (or similar properties washing machine), kodak RP-XOMAT rushed MYB, M35, M8,ALL-PRO100etc.


Using our medical rinses or kodak RPX - OMAT rinse can be obtained better photo.

       Artificially flush

 
  Reference Formulas Tempreture Time
developing Agfa-30 D-19b 20℃ 4~6mins
fixing F-5 20℃ 10mins
washing   Room tempreture 15mins
    Usable also kodak GBX enhancement and fuser wash with type medicine or rinse medicine。
 
Remark
 
    Usage:
Be careful when handling film, prevent fat, because of stress, and the fingerprint folding etc
    Storage:

         Store in a cool, dry place (The suitable temperature is 10-20℃,the humidity is 30%RH-60%RH). Keep it away from dampness, high temperature, any bad effective gases, x-ray, gamma ray or any other penetrating rays.Stored vertically to avoid any harmful effect caused by pressure.
Safety light:
Use a safe-light filter (dark red) in a suitable safelight lamp equipped with a 15-watt bulb. Keep the film at least 4 feet (1.2 meters) from the safelight, and the total lighting time is in 10 minutes.

 
    EXP
 
 This product in the storage conditions, service for 24 months.

 

 
 
All rights reserved©At ShenBei (group) Co., Ltd., Shanghai factory
Address:Shanghai lintong road 170 Zipcode:200082 Email:SH@smpicgg.com 网站建设中国企业港